Low smoke.
Reliable connections.
Explore single-core, multicore, armoured and control cables.
View construction, specifications and datasheets in one place.
FLC-LSHF-SL 600SSingle core · Non-sheathed
0.6/1 (1.2) kV · 90 °CIEC 60502-1 · IEC 60332-3 Cat. C
Stranded copper conductor
Cross-linked LSHF insulation
View details
- Applications
- Installation in conduits and open trays, as described in the datasheet.
- Construction
- Concentric lay round stranded copper with cross-linked low smoke and halogen free insulation. No separate outer sheath.
- Insulation colour
- Black is listed; other colours are available on request. The illustration shows the orange option.
- Listed sizes
- Single core; size designations from 1C × 1.5 to 1C × 630 mm². Refer to the PDF table for dimensions and packing.
- Voltage and temperature
- Rated voltage 0.6/1 (1.2) kV; circuit voltage not exceeding 1,000 V. Maximum conductor temperature 90 °C.
- AC test voltage
- 3.5 kV.
- Reference standards
- IEC 60502-1; IEC 60332-3; IEC 61034; IEC 60754-1; IEC 60754-2.
- Standard packing
- Refer to the PDF table for the selected size and core configuration.
FLC-LSHF 600SSingle core · LSHF sheathed
0.6/1 (1.2) kV · 90 °CIEC 60502-1 · IEC 60332-3 Cat. C
Stranded copper · Natural insulation
Separate LSHF outer sheath
View details
- Applications
- Installation in conduits and open trays, as described in the datasheet.
- Conductor
- Concentric lay round stranded copper.
- Insulation
- Cross-linked low smoke and halogen free compound, natural colour.
- Outer sheath
- Low smoke and halogen free flame-retardant compound, LSHF type ST8. Black is listed; other colours are available on request. Orange is shown.
- Listed sizes
- Single core; size designations from 1C × 1.5 to 1C × 630 mm². Refer to the PDF table.
- Voltage and temperature
- Rated voltage 0.6/1 (1.2) kV; circuit voltage not exceeding 1,000 V. Maximum conductor temperature 90 °C.
- AC test voltage
- 3.5 kV.
- Reference standards
- IEC 60502-1; IEC 60332-3; IEC 61034; IEC 60754-1; IEC 60754-2.
- Standard packing
- Refer to the PDF table for the selected size and core configuration.
FLC-LSHF 600MMulticore · Unarmoured
0.6/1 (1.2) kV · 90 °CIEC 60502-1 · IEC 60332-3 Cat. C
Individually insulated copper cores
Filler, wrapping tape and LSHF sheath
View details
- Applications
- Installation in conduits and open trays, as described in the datasheet.
- Conductor
- Concentric lay round stranded copper.
- Insulation
- Cross-linked low smoke and halogen free compound. The two-core illustration shows blue and brown cores; confirm core identification for the selected configuration.
- Filler and wrapping
- Nonhygroscopic LSHF rod or polypropylene filler, with flame-retardant wrapping tape.
- Outer sheath
- Low smoke and halogen free flame-retardant compound, LSHF type ST8. Black is listed; other colours are available on request. Orange is shown.
- Listed configurations
- Two, three and four cores, 1.5–400 mm². The product image shows a two-core example. No armour.
- Voltage and temperature
- Rated voltage 0.6/1 (1.2) kV; circuit voltage not exceeding 1,000 V. Maximum conductor temperature 90 °C.
- AC test voltage
- 3.5 kV.
- Reference standards
- IEC 60502-1; IEC 60332-3; IEC 61034; IEC 60754-1; IEC 60754-2.
- Standard packing
- Refer to the PDF table for the selected size and core configuration.
FLC-LSHF 600SWith armour · AWA
0.6/1 (1.2) kV · 90 °CIEC 60502-1 · IEC 60332-3 Cat. C
Single copper core · LSHF bedding
Aluminium wire armour and LSHF sheath
View details
- Applications
- Installation in conduits and open trays, as described in the datasheet.
- Conductor and insulation
- Concentric lay round stranded copper with natural-coloured cross-linked low smoke and halogen free insulation.
- Bedding
- Low smoke and halogen free flame-retardant compound, LSHF type ST8. Orange is listed; other colours are available on request.
- Armour
- Aluminium wire armour (AWA).
- Wrapping tape
- Flame-retardant tape.
- Outer sheath
- Low smoke and halogen free flame-retardant compound, LSHF type ST8. Black is listed; orange is shown as an optional colour.
- Listed sizes
- Single core; size designations from 1C × 1.5 to 1C × 630 mm². Refer to the PDF table.
- Voltage and temperature
- Rated voltage 0.6/1 (1.2) kV; circuit voltage not exceeding 1,000 V. Maximum conductor temperature 90 °C.
- AC test voltage
- 3.5 kV.
- Reference standards
- IEC 60502-1; IEC 60332-3; IEC 61034; IEC 60754-1; IEC 60754-2.
- Standard packing
- Refer to the PDF table for the selected size and core configuration.
FLC-LSHF 600MWith armour · SWA
0.6/1 (1.2) kV · 90 °CIEC 60502-1 · IEC 60332-3 Cat. C
Multiple copper cores · LSHF bedding
Steel wire armour and LSHF sheath
View details
- Applications
- Installation in conduits and open trays, as described in the datasheet.
- Conductor
- Concentric lay round stranded copper.
- Insulation
- Cross-linked low smoke and halogen free compound. The Construction text lists natural colour, while the source drawing shows colour-coded cores; confirm identification when ordering.
- Filler and bedding
- Nonhygroscopic LSHF rod filler and orange LSHF type ST8 bedding.
- Armour
- Galvanized steel wire armour (SWA), with flame-retardant wrapping tape.
- Outer sheath
- Orange low smoke and halogen free flame-retardant compound, LSHF type ST8. Other colours are available on request.
- Listed configurations
- Two, three and four cores, 1.5–400 mm². The product image shows a two-core example.
- Voltage and temperature
- Rated voltage 0.6/1 (1.2) kV; circuit voltage not exceeding 1,000 V. Maximum conductor temperature 90 °C.
- AC test voltage
- 3.5 kV.
- Reference standards
- IEC 60502-1; IEC 60332-3; IEC 61034; IEC 60754-1; IEC 60754-2.
- Standard packing
- Refer to the PDF table for the selected size and core configuration.
FLC-LSHF 600MControl cable · Numbered cores
0.6/1 (1.2) kV · 90 °CIEC 60502-1 · IEC 60332-3 Cat. C
Black insulated, numbered copper cores
Flame-retardant wrapping and LSHF sheath
View details
- Applications
- Installation in conduits and open trays, as described in the datasheet.
- Conductor
- Concentric lay round stranded copper.
- Insulation and identification
- Cross-linked low smoke and halogen free compound; black cores with number marking.
- Filler and wrapping
- Nonhygroscopic LSHF rod or polypropylene filler, with flame-retardant wrapping tape.
- Outer sheath
- Low smoke and halogen free flame-retardant compound, LSHF type ST8. Black is listed; other colours are available on request. Orange is shown.
- Listed configurations
- 2–30 cores; listed conductor sizes are 1.5, 2.5, 4, 6 and 10 mm². The product image shows a four-core example.
- Flame propagation categories
- The reference section lists IEC 60332-3 categories A, B and C. The footnote identifies the tabulated product codes as Category C.
- Voltage and temperature
- Rated voltage 0.6/1 (1.2) kV; circuit voltage not exceeding 1,000 V. Maximum conductor temperature 90 °C.
- AC test voltage
- 3.5 kV.
- Reference standards
- IEC 60502-1; IEC 60332-3; IEC 61034; IEC 60754-1; IEC 60754-2.
- Standard packing
- Refer to the PDF table for the selected size and core configuration.