CTW | Instrument & Control Cables
INSTRUMENT & CONTROL COLLECTION

Reliable signals.
Precise control.

Explore instrument, control and power cables.
View construction, specifications and datasheets in one place.

23Product datasheets 3Application groups PDFTechnical specifications

Select “View details” for specifications or “Download PDF” for the datasheet. Use your browser’s Find in Page to search.

Explore products (23)

Control circuitsFILE 01
CTW-CVV 600 V cable illustration, concentric stranded annealed copper, unscreened and black PVC sheath

CTW-CVV

600 V · 75 °CICEA S-61-402 (NEMA WC 5)

Stranded copper · PVC insulation
Unscreened

2–30 cores• PDF 8 pages
View details
Applications
Supervisory electrical equipment and station control circuits; outdoor installation in wet or dry cable trenches, as described in the datasheet.
Reference standard
ICEA S-61-402 (NEMA WC 5)
Rated voltage / temperature
600 V; maximum conductor temperature 75 °C.
Conductor
Concentric stranded annealed copper.
Nominal conductor sizes
0.5, 0.75, 1, 1.5, 2.5, 4, 6, 10 mm²; refer to the PDF for the listed combinations.
Core configurations
2–30 cores, in the configurations listed in the PDF.
Insulation
Black PVC with number marking; other identification colours may be supplied to special order.
Filler and wrapping
Non-hygroscopic PVC rod and/or polypropylene filler; polyester (Mylar) wrapping tape.
Screen
No metallic screen specified.
Outer sheath
Black PVC.
Optional sheath
Special flame-retardant PVC can be supplied on request; see PDF.

Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.

Read full datasheet — 8 pages ↗
Control circuitsFILE 02
CTW-CVVS 600 V cable illustration, concentric stranded annealed copper, copper tape screen and black PVC sheath

CTW-CVVS

600 V · 75 °CICEA S-61-402 (NEMA WC 5)

Stranded copper · PVC insulation
Copper tape screen

2–30 cores• PDF 8 pages
View details
Applications
Supervisory electrical equipment and station control circuits; outdoor installation in wet or dry cable trenches, as described in the datasheet.
Reference standard
ICEA S-61-402 (NEMA WC 5)
Rated voltage / temperature
600 V; maximum conductor temperature 75 °C.
Conductor
Concentric stranded annealed copper.
Nominal conductor sizes
0.5, 0.75, 1, 1.5, 2.5, 4, 6, 10 mm²; refer to the PDF for the listed combinations.
Core configurations
2–30 cores, in the configurations listed in the PDF.
Insulation
Black PVC with number marking; other identification colours may be supplied to special order.
Filler and wrapping
Non-hygroscopic PVC rod and/or polypropylene filler; polyester (Mylar) wrapping tape.
Bedding
Black PVC.
Screen
Annealed copper tape.
Separator
Polyester (Mylar) tape.
Outer sheath
Black PVC.
Optional sheath
Special flame-retardant PVC can be supplied on request; see PDF.

Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.

Read full datasheet — 8 pages ↗
Control circuitsFILE 03
CTW-FCVV 600 V cable illustration, flexible bunched annealed copper, unscreened and black PVC sheath

CTW-FCVV

600 V · 75 °CICEA S-61-402 (NEMA WC 5)

Flexible copper · PVC insulation
Unscreened

2–30 cores• PDF 8 pages
View details
Applications
Supervisory electrical equipment and station control circuits; outdoor installation in wet or dry cable trenches, as described in the datasheet.
Reference standard
ICEA S-61-402 (NEMA WC 5)
Rated voltage / temperature
600 V; maximum conductor temperature 75 °C.
Conductor
Flexible bunched annealed copper.
Nominal conductor sizes
0.5, 0.75, 1, 1.5, 2.5, 4, 6, 10 mm²; refer to the PDF for the listed combinations.
Core configurations
2–30 cores, in the configurations listed in the PDF.
Insulation
Black PVC with number marking; other identification colours may be supplied to special order.
Filler and wrapping
Non-hygroscopic PVC rod and/or polypropylene filler; polyester (Mylar) wrapping tape.
Screen
No metallic screen specified.
Outer sheath
Black PVC.
Optional sheath
Special flame-retardant PVC can be supplied on request; see PDF.

Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.

Read full datasheet — 8 pages ↗
Control circuitsFILE 04
CTW-FCVVS 600 V cable illustration, flexible bunched annealed copper, copper tape screen and black PVC sheath

CTW-FCVVS

600 V · 75 °CICEA S-61-402 (NEMA WC 5)

Flexible copper · PVC insulation
Copper tape screen

2–30 cores• PDF 8 pages
View details
Applications
Supervisory electrical equipment and station control circuits; outdoor installation in wet or dry cable trenches, as described in the datasheet.
Reference standard
ICEA S-61-402 (NEMA WC 5)
Rated voltage / temperature
600 V; maximum conductor temperature 75 °C.
Conductor
Flexible bunched annealed copper.
Nominal conductor sizes
0.5, 0.75, 1, 1.5, 2.5, 4, 6, 10 mm²; refer to the PDF for the listed combinations.
Core configurations
2–30 cores, in the configurations listed in the PDF.
Insulation
Black PVC with number marking; other identification colours may be supplied to special order.
Filler and wrapping
Non-hygroscopic PVC rod and/or polypropylene filler; polyester (Mylar) wrapping tape.
Bedding
Black PVC.
Screen
Annealed copper tape.
Separator
Polyester (Mylar) tape.
Outer sheath
Black PVC.
Optional sheath
Special flame-retardant PVC can be supplied on request; see PDF.

Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.

Read full datasheet — 8 pages ↗
Control circuitsFILE 05
CTW-CVV 600 V cable illustration, concentric stranded annealed copper, unscreened and black PVC sheath

CTW-CVV

600 V · 70 °CIEC 60502-1

Stranded copper · PVC insulation
Unscreened

2–30 cores• PDF 6 pages
View details
Applications
Supervisory electrical equipment and station control circuits; outdoor installation in wet or dry cable trenches, as described in the datasheet.
Reference standard
IEC 60502-1
Rated voltage / temperature
600 V; maximum conductor temperature 70 °C.
Conductor
Concentric stranded annealed copper.
Nominal conductor sizes
1.5, 2.5, 4, 6, 10 mm²; refer to the PDF for the listed combinations.
Core configurations
2–30 cores, in the configurations listed in the PDF.
Insulation
Black PVC with number marking; other identification colours may be supplied to special order.
Filler and wrapping
Non-hygroscopic PVC rod and/or polypropylene filler; polyester (Mylar) wrapping tape.
Screen
No metallic screen specified.
Outer sheath
Black PVC.
Optional sheath
Special flame-retardant PVC can be supplied on request; see PDF.

Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.

Read full datasheet — 6 pages ↗
Control circuitsFILE 06
CTW-CVVS 600 V cable illustration, concentric stranded annealed copper, copper tape screen and black PVC sheath

CTW-CVVS

600 V · 70 °CIEC 60502-1

Stranded copper · PVC insulation
Copper tape screen

2–30 cores• PDF 6 pages
View details
Applications
Supervisory electrical equipment and station control circuits; outdoor installation in wet or dry cable trenches, as described in the datasheet.
Reference standard
IEC 60502-1
Rated voltage / temperature
600 V; maximum conductor temperature 70 °C.
Conductor
Concentric stranded annealed copper.
Nominal conductor sizes
1.5, 2.5, 4, 6, 10 mm²; refer to the PDF for the listed combinations.
Core configurations
2–30 cores, in the configurations listed in the PDF.
Insulation
Black PVC with number marking; other identification colours may be supplied to special order.
Filler and wrapping
Non-hygroscopic PVC rod and/or polypropylene filler; polyester (Mylar) wrapping tape.
Bedding
Black PVC.
Screen
Annealed copper tape.
Separator
Polyester (Mylar) tape.
Outer sheath
Black PVC.
Optional sheath
Special flame-retardant PVC can be supplied on request; see PDF.

Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.

Read full datasheet — 6 pages ↗
Control circuitsFILE 07
CTW-CVV-SWA 600 V cable illustration, concentric stranded annealed copper, steel wire armour (swa) and black PVC sheath

CTW-CVV-SWA

600 V · 70 °CIEC 60502-1

Stranded copper · PVC insulation
Steel wire armour (SWA)

2–30 cores• PDF 6 pages
View details
Applications
Supervisory electrical equipment and station control circuits; outdoor installation in wet or dry cable trenches, as described in the datasheet.
Reference standard
IEC 60502-1
Rated voltage / temperature
600 V; maximum conductor temperature 70 °C.
Conductor
Concentric stranded annealed copper.
Nominal conductor sizes
1.5, 2.5, 4, 6, 10 mm²; refer to the PDF for the listed combinations.
Core configurations
2–30 cores, in the configurations listed in the PDF.
Insulation
Black PVC with number marking; other identification colours may be supplied to special order.
Filler and wrapping
Non-hygroscopic PVC rod and/or polypropylene filler; polyester (Mylar) wrapping tape.
Bedding
Black PVC.
Screen
No metallic screen specified.
Armour
Galvanized steel wire armour.
Separator
Polyester (Mylar) tape.
Outer sheath
Black PVC.
Optional sheath
Special flame-retardant PVC can be supplied on request; see PDF.

Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.

Read full datasheet — 6 pages ↗
Control circuitsFILE 08
CTW-FCVV 600 V cable illustration, flexible bunched annealed copper, unscreened and black PVC sheath

CTW-FCVV

600 V · 70 °CJIS C3401

Flexible copper · PVC insulation
Unscreened

2–30 cores• PDF 6 pages
View details
Applications
Supervisory electrical equipment and station control circuits; outdoor installation in wet or dry cable trenches, as described in the datasheet.
Reference standard
JIS C3401
Rated voltage / temperature
600 V; maximum conductor temperature 70 °C.
Conductor
Flexible bunched annealed copper.
Nominal conductor sizes
1, 1.5, 2.5, 4, 6 mm²; refer to the PDF for the listed combinations.
Core configurations
2–30 cores, in the configurations listed in the PDF.
Insulation
Black PVC with number marking; other identification colours may be supplied to special order.
Filler and wrapping
Non-hygroscopic PVC rod and/or polypropylene filler; polyester (Mylar) wrapping tape.
Screen
No metallic screen specified.
Outer sheath
Black PVC.
Optional sheath
Special flame-retardant PVC can be supplied on request; see PDF.

Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.

Read full datasheet — 6 pages ↗
Control circuitsFILE 09
CTW-FCVVS 600 V cable illustration, flexible bunched annealed copper, copper tape screen and black PVC sheath

CTW-FCVVS

600 V · 70 °CJIS C3401

Flexible copper · PVC insulation
Copper tape screen

2–30 cores• PDF 6 pages
View details
Applications
Supervisory electrical equipment and station control circuits; outdoor installation in wet or dry cable trenches, as described in the datasheet.
Reference standard
JIS C3401
Rated voltage / temperature
600 V; maximum conductor temperature 70 °C.
Conductor
Flexible bunched annealed copper.
Nominal conductor sizes
1, 1.5, 2.5, 4, 6 mm²; refer to the PDF for the listed combinations.
Core configurations
2–30 cores, in the configurations listed in the PDF.
Insulation
Black PVC with number marking; other identification colours may be supplied to special order.
Filler and wrapping
Non-hygroscopic PVC rod and/or polypropylene filler; polyester (Mylar) wrapping tape.
Bedding
Black PVC.
Screen
Annealed copper tape.
Separator
Polyester (Mylar) tape.
Outer sheath
Black PVC.
Optional sheath
Special flame-retardant PVC can be supplied on request; see PDF.

Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.

Read full datasheet — 6 pages ↗
Control circuitsFILE 10
CTW-CVVN-DSTA 750 V cable illustration with black insulated copper cores, double steel tape armour, black overall sheath, Nylon 12 layer and outer protective sheath

CTW-CVVN-DSTA

750 V · 70 °CBS 6346:1997

Double steel tape armour (DSTA)
Nylon 12 protective layer

2–30 cores• PDF 5 pages
View details
Applications
Control signals, signal lamps, point machines and other signalling equipment within an interlocked signal area, as described in the datasheet.
Reference standards
BS 6346:1997, BS 6360:1991 and BS 6746.
Rated voltage / temperature
750 V; maximum conductor temperature 70 °C.
Conductor
Plain annealed copper to BS 6360; solid or stranded according to the listed configuration.
Nominal conductor sizes
1.5, 2.5, 4, 6, 10, 16 and 25 mm². Available combinations depend on core count; see PDF.
Core configurations
2–30 cores, in the configurations listed in the PDF.
Insulation and identification
PVC Type TI1 to BS 6746; black cores with continuous number marking.
Wrapping
Wrapping tape around the core bundle, as shown in the construction drawing.
Bedding sheath
Black PVC Type TM1 to BS 6746.
Armour
Double galvanized steel tape armour (DSTA); tape thickness 0.2 mm.
Overall sheath
Black PVC Type TM1 to BS 6746, over the armour.
Termite protective layer
Nylon 12; thickness 0.5 mm, over the overall sheath.
Outer protective sheath
PVC Type TM1 to BS 6746, over the Nylon 12 layer.
AC test voltage
3 kV, as specified in the supplied datasheet.

Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.

Read full datasheet — 5 pages ↗
Control circuitsFILE 11
CTW-NYCY 750 V control cable illustration with concentric copper wires with a helix of copper tape

CTW-NYCYControl cable

750 V · 70 °CTIS 11-2531 · VDE 0271

PVC insulation · Double sheath
Copper wire + tape screen

2–37 cores• PDF 1 page
View details
Applications
Exposed installation or installation in raceways, in wet or dry locations, or direct burial, as described in the datasheet.
Reference standard
TIS 11-2531 / VDE 0271, where applicable
Rated voltage / temperature
750 V; maximum conductor temperature 70 °C.
Conductor
Concentric stranded annealed copper.
Nominal conductor sizes
2.5 mm²; see PDF for individual sizes and configurations.
Core configurations
2, 3, 4, 5, 6, 7, 12, 19, 27 or 37 cores.
Insulation and identification
PVC. 2 cores: red / black; 3 cores: red / yellow / blue; 4 cores: red / yellow / blue / black. More than 4 cores: black with white number marking.
Inner sheath
Black PVC.
Concentric screen
Concentric copper wires with a helix of copper tape.
Outer sheath
Black PVC.
Test voltage
2,500 V, as specified in the supplied datasheet.

Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.

Read full datasheet — 1 page ↗
Power distributionFILE 12
CTW-NYCY 750 V power cable illustration with concentric copper wires with a helix of copper tape

CTW-NYCYPower cable

750 V · 70 °CTIS 11-2531 · VDE 0271

PVC insulation · Double sheath
Copper wire + tape screen

2, 3 or 4 cores• PDF 3 pages
View details
Applications
Exposed installation or installation in raceways, in wet or dry locations, or direct burial, as described in the datasheet.
Reference standard
TIS 11-2531 / VDE 0271, where applicable
Rated voltage / temperature
750 V; maximum conductor temperature 70 °C.
Conductor
Concentric stranded annealed copper.
Nominal conductor sizes
1.5–300 mm²; see PDF for individual sizes and configurations.
Core configurations
2, 3 or 4 cores.
Insulation and identification
PVC. 2 cores: red / black; 3 cores: red / yellow / blue; 4 cores: red / yellow / blue / black.
Inner sheath
Black PVC.
Concentric screen
Concentric copper wires with a helix of copper tape.
Outer sheath
Black PVC.
Test voltage
2,500 V, as specified in the supplied datasheet.

Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.

Read full datasheet — 3 pages ↗
Power distributionFILE 13
CTW-NYY-SWA 750 V armoured power cable illustration with galvanized steel wire armour

CTW-NYY-SWA

750 V · 70 °CApplied TIS 11-2531

PVC insulation · Double sheath
Steel wire armour (SWA)

2, 3 or 4 cores• PDF 3 pages
View details
Applications
Exposed installation or installation in raceways, in wet or dry locations, or direct burial, as described in the datasheet.
Reference standard
Applied TIS 11-2531
Rated voltage / temperature
750 V; maximum conductor temperature 70 °C.
Conductor
Solid or stranded annealed copper according to the listed size.
Nominal conductor sizes
1–300 mm²; see PDF for individual sizes and configurations.
Core configurations
2, 3 or 4 cores.
Insulation and identification
PVC. 2 cores: light grey / black; 3 cores: light grey / black / red; 4 cores: light grey / black / red / blue.
Inner sheath
Black PVC.
Armour
Galvanized steel wire armour.
Outer sheath
Black PVC.
Test voltage
2,500 V, as specified in the supplied datasheet.

Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.

Read full datasheet — 3 pages ↗
InstrumentationFILE 14
CTW-RE-2Y(ST)Y-PR cable illustration with PE insulation, collective foil screen and black PVC sheath

CTW-RE-2Y(ST)Y-PR

300/500 V · 65 °CBS 5308 Part 1 Type 1

Collective aluminium foil screen
PE insulation · Unarmoured

1–50 pairs• PDF 2 pages
View details
Applications
Transmission of analogue and digital signals in instrument and control systems. Indoor and outdoor installation in dry or wet locations on racks or in conduits. The supplied datasheet does not recommend direct burial and prohibits direct connection to a low-impedance source such as public mains electricity.
Reference standard
BS 5308 Part 1 Type 1
Rated voltage / temperature
300/500 V; maximum conductor operating temperature +65 °C.
Conductor
Plain annealed copper to BS 6360; solid, flexible or stranded, depending on nominal size and the listed configuration.
Nominal conductor sizes
0.5, 1.0, 1.5 mm²; available combinations vary by size.
Core configuration
Twisted pairs; 1–50 pairs. See PDF for the individual configurations.
Insulation
Polyethylene (PE) Type 03 to BS 6234.
Wrapping
At least one layer of polyester tape.
Collective screen
Aluminium foil in contact with a 0.5 mm² tinned-copper drain wire.
Outer sheath
Black PVC Type TM1 to BS 6746.
Minimum bending radius
6 × overall cable diameter.
Optional sheath
Special flame-retardant PVC or low-smoke halogen-free (LSHF) material can be requested; refer to the PDF for the corresponding requirements.

Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.

Read full datasheet — 2 pages ↗
InstrumentationFILE 15
CTW-RE-2Y(ST)Y-PS cable illustration with PE insulation, individual and collective foil screens and black PVC sheath

CTW-RE-2Y(ST)Y-PS

300/500 V · 65 °CBS 5308 Part 1 Type 1

Individual + collective screens
PE insulation · Unarmoured

2–50 pairs• PDF 2 pages
View details
Applications
Transmission of analogue and digital signals in instrument and control systems. Indoor and outdoor installation in dry or wet locations on racks or in conduits. The supplied datasheet does not recommend direct burial and prohibits direct connection to a low-impedance source such as public mains electricity.
Reference standard
BS 5308 Part 1 Type 1
Rated voltage / temperature
300/500 V; maximum conductor operating temperature +65 °C.
Conductor
Plain annealed copper to BS 6360; solid, flexible or stranded, depending on nominal size and the listed configuration.
Nominal conductor sizes
0.5, 1.0, 1.5 mm²; available combinations vary by size.
Core configuration
Twisted pairs; 2–50 pairs. See PDF for the individual configurations.
Insulation
Polyethylene (PE) Type 03 to BS 6234.
Individual pair screens
Aluminium foil in contact with a 0.5 mm² tinned-copper drain wire for each screened pair.
Wrapping
At least one layer of polyester tape.
Collective screen
Aluminium foil in contact with a 0.5 mm² tinned-copper drain wire.
Outer sheath
Black PVC Type TM1 to BS 6746.
Minimum bending radius
6 × overall cable diameter.
Optional sheath
Special flame-retardant PVC or low-smoke halogen-free (LSHF) material can be requested; refer to the PDF for the corresponding requirements.

Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.

Read full datasheet — 2 pages ↗
InstrumentationFILE 16
CTW-RE-2Y(ST)2YSWAY-PR cable illustration with PE insulation, collective foil screen and steel wire armour

CTW-RE-2Y(ST)2YSWAY-PR

300/500 V · 65 °CBS 5308 Part 1 Type 2

Collective aluminium foil screen
PE insulation · SWA

1–50 pairs• PDF 2 pages
View details
Applications
Transmission of analogue and digital signals in instrument and control systems. Indoor and outdoor installation in dry or wet locations on racks or in conduits. The supplied datasheet does not recommend direct burial and prohibits direct connection to a low-impedance source such as public mains electricity.
Reference standard
BS 5308 Part 1 Type 2
Rated voltage / temperature
300/500 V; maximum conductor operating temperature +65 °C.
Conductor
Plain annealed copper to BS 6360; solid, flexible or stranded, depending on nominal size and the listed configuration.
Nominal conductor sizes
0.5, 1.0, 1.5 mm²; available combinations vary by size.
Core configuration
Twisted pairs; 1–50 pairs. See PDF for the individual configurations.
Insulation
Polyethylene (PE) Type 03 to BS 6234.
Wrapping
At least one layer of polyester tape.
Collective screen
Aluminium foil in contact with a 0.5 mm² tinned-copper drain wire.
Bedding
Black PE Type 03.
Armour
Galvanized round steel wire (SWA).
Outer sheath
Black PVC Type TM1 to BS 6746.
Minimum bending radius
8 × overall cable diameter.
Optional sheath
Special flame-retardant PVC or low-smoke halogen-free (LSHF) material can be requested; refer to the PDF for the corresponding requirements.

Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.

Read full datasheet — 2 pages ↗
InstrumentationFILE 17
CTW-RE-2Y(ST)2YSWAY-PS cable illustration with PE insulation, individual and collective foil screens and steel wire armour

CTW-RE-2Y(ST)2YSWAY-PS

300/500 V · 65 °CBS 5308 Part 1 Type 2

Individual + collective screens
PE insulation · SWA

2–50 pairs• PDF 2 pages
View details
Applications
Transmission of analogue and digital signals in instrument and control systems. Indoor and outdoor installation in dry or wet locations on racks or in conduits. The supplied datasheet does not recommend direct burial and prohibits direct connection to a low-impedance source such as public mains electricity.
Reference standard
BS 5308 Part 1 Type 2
Rated voltage / temperature
300/500 V; maximum conductor operating temperature +65 °C.
Conductor
Plain annealed copper to BS 6360; solid, flexible or stranded, depending on nominal size and the listed configuration.
Nominal conductor sizes
0.5, 1.0, 1.5 mm²; available combinations vary by size.
Core configuration
Twisted pairs; 2–50 pairs. See PDF for the individual configurations.
Insulation
Polyethylene (PE) Type 03 to BS 6234.
Individual pair screens
Aluminium foil in contact with a 0.5 mm² tinned-copper drain wire for each screened pair.
Wrapping
At least one layer of polyester tape.
Collective screen
Aluminium foil in contact with a 0.5 mm² tinned-copper drain wire.
Bedding
Black PE Type 03.
Armour
Galvanized round steel wire (SWA).
Outer sheath
Black PVC Type TM1 to BS 6746.
Minimum bending radius
8 × overall cable diameter.
Optional sheath
Special flame-retardant PVC or low-smoke halogen-free (LSHF) material can be requested; refer to the PDF for the corresponding requirements.

Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.

Read full datasheet — 2 pages ↗
InstrumentationFILE 18
CTW-RE-Y(ST)Y-PR cable illustration with PVC insulation, collective foil screen and black PVC sheath

CTW-RE-Y(ST)Y-PR

300/500 V · 65 °CBS 5308 Part 2 Type 1

Collective aluminium foil screen
PVC insulation · Unarmoured

1–50 pairs• PDF 2 pages
View details
Applications
Transmission of analogue and digital signals in instrument and control systems. Indoor and outdoor installation in dry or wet locations on racks or in conduits. The supplied datasheet does not recommend direct burial and prohibits direct connection to a low-impedance source such as public mains electricity.
Reference standard
BS 5308 Part 2 Type 1
Rated voltage / temperature
300/500 V; maximum conductor operating temperature +65 °C.
Conductor
Plain annealed copper to BS 6360; 0.5 and 0.75 mm² flexible conductors, or 1.5 mm² stranded conductors, as listed in the PDF.
Nominal conductor sizes
0.5, 0.75, 1.5 mm²; available combinations vary by size.
Core configuration
Twisted pairs; 1–50 pairs. See PDF for the individual configurations.
Insulation
Polyvinyl chloride (PVC); refer to the PDF for identification and compound details.
Wrapping
At least one layer of polyester tape.
Collective screen
Aluminium foil in contact with a 0.5 mm² tinned-copper drain wire.
Outer sheath
Black PVC Type TM1 to BS 6746.
Minimum bending radius
6 × overall cable diameter.
Optional sheath
Special flame-retardant PVC or low-smoke halogen-free (LSHF) material can be requested; refer to the PDF for the corresponding requirements.

Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.

Read full datasheet — 2 pages ↗
InstrumentationFILE 19
CTW-RE-Y(ST)Y-PS cable illustration with PVC insulation, individual and collective foil screens and black PVC sheath

CTW-RE-Y(ST)Y-PS

300/500 V · 65 °CBS 5308 Part 2 Type 1

Individual + collective screens
PVC insulation · Unarmoured

2–50 pairs• PDF 2 pages
View details
Applications
Transmission of analogue and digital signals in instrument and control systems. Indoor and outdoor installation in dry or wet locations on racks or in conduits. The supplied datasheet does not recommend direct burial and prohibits direct connection to a low-impedance source such as public mains electricity.
Reference standard
BS 5308 Part 2 Type 1
Rated voltage / temperature
300/500 V; maximum conductor operating temperature +65 °C.
Conductor
Plain annealed copper to BS 6360; 0.5 and 0.75 mm² flexible conductors, or 1.5 mm² stranded conductors, as listed in the PDF.
Nominal conductor sizes
0.5, 0.75, 1.5 mm²; available combinations vary by size.
Core configuration
Twisted pairs; 2–50 pairs. See PDF for the individual configurations.
Insulation
Polyvinyl chloride (PVC); refer to the PDF for identification and compound details.
Individual pair screens
Aluminium foil in contact with a 0.5 mm² tinned-copper drain wire for each screened pair.
Wrapping
At least one layer of polyester tape.
Collective screen
Aluminium foil in contact with a 0.5 mm² tinned-copper drain wire.
Outer sheath
Black PVC Type TM1 to BS 6746.
Minimum bending radius
6 × overall cable diameter.
Optional sheath
Special flame-retardant PVC or low-smoke halogen-free (LSHF) material can be requested; refer to the PDF for the corresponding requirements.

Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.

Read full datasheet — 2 pages ↗
InstrumentationFILE 20
CTW-RE-Y(ST)Y-CO cable illustration with PVC insulation, collective foil screen and black PVC sheath

CTW-RE-Y(ST)Y-CO

300/500 V · 65 °CBS 5308 Part 2 Type 1

Collective aluminium foil screen
PVC insulation · Unarmoured

2–40 cores• PDF 2 pages
View details
Applications
Transmission of analogue and digital signals in instrument and control systems. Indoor and outdoor installation in dry or wet locations on racks or in conduits. The supplied datasheet does not recommend direct burial and prohibits direct connection to a low-impedance source such as public mains electricity.
Reference standard
BS 5308 Part 2 Type 1
Rated voltage / temperature
300/500 V; maximum conductor operating temperature +65 °C.
Conductor
Plain annealed copper to BS 6360; 0.5 and 0.75 mm² flexible conductors, or 1.5 mm² stranded conductors, as listed in the PDF.
Nominal conductor sizes
0.5, 0.75, 1.5 mm²; available combinations vary by size.
Core configuration
Multicore (CO); 2–40 cores. See PDF for the individual configurations.
Insulation
Polyvinyl chloride (PVC); refer to the PDF for identification and compound details.
Wrapping
At least one layer of polyester tape.
Collective screen
Aluminium foil in contact with a 0.5 mm² tinned-copper drain wire.
Outer sheath
Black PVC Type TM1 to BS 6746.
Minimum bending radius
8 × overall cable diameter.
Optional sheath
Special flame-retardant PVC or low-smoke halogen-free (LSHF) material can be requested; refer to the PDF for the corresponding requirements.

Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.

Read full datasheet — 2 pages ↗
InstrumentationFILE 21
CTW-RE-Y(ST)YSWAY-CO cable illustration with PVC insulation, collective foil screen and steel wire armour

CTW-RE-Y(ST)YSWAY-CO

300/500 V · 65 °CBS 5308 Part 2 Type 2

Collective aluminium foil screen
PVC insulation · SWA

2–40 cores• PDF 2 pages
View details
Applications
Transmission of analogue and digital signals in instrument and control systems. Indoor and outdoor installation in dry or wet locations on racks or in conduits. The supplied datasheet does not recommend direct burial and prohibits direct connection to a low-impedance source such as public mains electricity.
Reference standard
BS 5308 Part 2 Type 2
Rated voltage / temperature
300/500 V; maximum conductor operating temperature +65 °C.
Conductor
Plain annealed copper to BS 6360; 0.5 and 0.75 mm² flexible conductors, or 1.5 mm² stranded conductors, as listed in the PDF.
Nominal conductor sizes
0.5, 0.75, 1.5 mm²; available combinations vary by size.
Core configuration
Multicore (CO); 2–40 cores. See PDF for the individual configurations.
Insulation
Polyvinyl chloride (PVC); refer to the PDF for identification and compound details.
Wrapping
At least one layer of polyester tape.
Collective screen
Aluminium foil in contact with a 0.5 mm² tinned-copper drain wire.
Bedding
Black PVC.
Armour
Galvanized round steel wire (SWA).
Outer sheath
Black PVC Type TM1 to BS 6746.
Minimum bending radius
8 × overall cable diameter.
Optional sheath
Special flame-retardant PVC or low-smoke halogen-free (LSHF) material can be requested; refer to the PDF for the corresponding requirements.

Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.

Read full datasheet — 2 pages ↗
InstrumentationFILE 22
CTW-RE-Y(ST)YSWAY-PR cable illustration with PVC insulation, collective foil screen and steel wire armour

CTW-RE-Y(ST)YSWAY-PR

300/500 V · 65 °CBS 5308 Part 2 Type 2

Collective aluminium foil screen
PVC insulation · SWA

1–50 pairs• PDF 2 pages
View details
Applications
Transmission of analogue and digital signals in instrument and control systems. Indoor and outdoor installation in dry or wet locations on racks or in conduits. The supplied datasheet does not recommend direct burial and prohibits direct connection to a low-impedance source such as public mains electricity.
Reference standard
BS 5308 Part 2 Type 2
Rated voltage / temperature
300/500 V; maximum conductor operating temperature +65 °C.
Conductor
Plain annealed copper to BS 6360; 0.5 and 0.75 mm² flexible conductors, or 1.5 mm² stranded conductors, as listed in the PDF.
Nominal conductor sizes
0.5, 0.75, 1.5 mm²; available combinations vary by size.
Core configuration
Twisted pairs; 1–50 pairs. See PDF for the individual configurations.
Insulation
Polyvinyl chloride (PVC); refer to the PDF for identification and compound details.
Wrapping
At least one layer of polyester tape.
Collective screen
Aluminium foil in contact with a 0.5 mm² tinned-copper drain wire.
Bedding
Black PVC.
Armour
Galvanized round steel wire (SWA).
Outer sheath
Black PVC Type TM1 to BS 6746.
Minimum bending radius
8 × overall cable diameter.
Optional sheath
Special flame-retardant PVC or low-smoke halogen-free (LSHF) material can be requested; refer to the PDF for the corresponding requirements.

Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.

Read full datasheet — 2 pages ↗
InstrumentationFILE 23
CTW-RE-Y(ST)YSWAY-PS cable illustration with PVC insulation, individual and collective foil screens and steel wire armour

CTW-RE-Y(ST)YSWAY-PS

300/500 V · 65 °CBS 5308 Part 2 Type 2

Individual + collective screens
PVC insulation · SWA

2–50 pairs• PDF 2 pages
View details
Applications
Transmission of analogue and digital signals in instrument and control systems. Indoor and outdoor installation in dry or wet locations on racks or in conduits. The supplied datasheet does not recommend direct burial and prohibits direct connection to a low-impedance source such as public mains electricity.
Reference standard
BS 5308 Part 2 Type 2
Rated voltage / temperature
300/500 V; maximum conductor operating temperature +65 °C.
Conductor
Plain annealed copper to BS 6360; 0.5 and 0.75 mm² flexible conductors, or 1.5 mm² stranded conductors, as listed in the PDF.
Nominal conductor sizes
0.5, 0.75, 1.5 mm²; available combinations vary by size.
Core configuration
Twisted pairs; 2–50 pairs. See PDF for the individual configurations.
Insulation
Polyvinyl chloride (PVC); refer to the PDF for identification and compound details.
Individual pair screens
Aluminium foil in contact with a 0.5 mm² tinned-copper drain wire for each screened pair.
Wrapping
At least one layer of polyester tape.
Collective screen
Aluminium foil in contact with a 0.5 mm² tinned-copper drain wire.
Bedding
Black PVC.
Armour
Galvanized round steel wire (SWA).
Outer sheath
Black PVC Type TM1 to BS 6746.
Minimum bending radius
8 × overall cable diameter.
Optional sheath
Special flame-retardant PVC or low-smoke halogen-free (LSHF) material can be requested; refer to the PDF for the corresponding requirements.

Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.

Read full datasheet — 2 pages ↗
No products match your search. Try another term or clear the filters.

CHAROONG THAI WIRE & CABLE PUBLIC COMPANY LIMITED

Conductor cross-sectional areas are stated in mm². Refer to each supplied PDF for available sizes, electrical characteristics and packing details.

Product illustrations show example constructions and are not to scale. Core counts, conductor stranding and layer thicknesses vary by configuration. The original datasheet is the specification reference.