Reliable signals.
Precise control.
Explore instrument, control and power cables.
View construction, specifications and datasheets in one place.
CTW-CVV
600 V · 75 °CICEA S-61-402 (NEMA WC 5)
Stranded copper · PVC insulation
Unscreened
View details
- Applications
- Supervisory electrical equipment and station control circuits; outdoor installation in wet or dry cable trenches, as described in the datasheet.
- Reference standard
- ICEA S-61-402 (NEMA WC 5)
- Rated voltage / temperature
- 600 V; maximum conductor temperature 75 °C.
- Conductor
- Concentric stranded annealed copper.
- Nominal conductor sizes
- 0.5, 0.75, 1, 1.5, 2.5, 4, 6, 10 mm²; refer to the PDF for the listed combinations.
- Core configurations
- 2–30 cores, in the configurations listed in the PDF.
- Insulation
- Black PVC with number marking; other identification colours may be supplied to special order.
- Filler and wrapping
- Non-hygroscopic PVC rod and/or polypropylene filler; polyester (Mylar) wrapping tape.
- Screen
- No metallic screen specified.
- Outer sheath
- Black PVC.
- Optional sheath
- Special flame-retardant PVC can be supplied on request; see PDF.
Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.
Read full datasheet — 8 pages ↗
CTW-CVVS
600 V · 75 °CICEA S-61-402 (NEMA WC 5)
Stranded copper · PVC insulation
Copper tape screen
View details
- Applications
- Supervisory electrical equipment and station control circuits; outdoor installation in wet or dry cable trenches, as described in the datasheet.
- Reference standard
- ICEA S-61-402 (NEMA WC 5)
- Rated voltage / temperature
- 600 V; maximum conductor temperature 75 °C.
- Conductor
- Concentric stranded annealed copper.
- Nominal conductor sizes
- 0.5, 0.75, 1, 1.5, 2.5, 4, 6, 10 mm²; refer to the PDF for the listed combinations.
- Core configurations
- 2–30 cores, in the configurations listed in the PDF.
- Insulation
- Black PVC with number marking; other identification colours may be supplied to special order.
- Filler and wrapping
- Non-hygroscopic PVC rod and/or polypropylene filler; polyester (Mylar) wrapping tape.
- Bedding
- Black PVC.
- Screen
- Annealed copper tape.
- Separator
- Polyester (Mylar) tape.
- Outer sheath
- Black PVC.
- Optional sheath
- Special flame-retardant PVC can be supplied on request; see PDF.
Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.
Read full datasheet — 8 pages ↗
CTW-FCVV
600 V · 75 °CICEA S-61-402 (NEMA WC 5)
Flexible copper · PVC insulation
Unscreened
View details
- Applications
- Supervisory electrical equipment and station control circuits; outdoor installation in wet or dry cable trenches, as described in the datasheet.
- Reference standard
- ICEA S-61-402 (NEMA WC 5)
- Rated voltage / temperature
- 600 V; maximum conductor temperature 75 °C.
- Conductor
- Flexible bunched annealed copper.
- Nominal conductor sizes
- 0.5, 0.75, 1, 1.5, 2.5, 4, 6, 10 mm²; refer to the PDF for the listed combinations.
- Core configurations
- 2–30 cores, in the configurations listed in the PDF.
- Insulation
- Black PVC with number marking; other identification colours may be supplied to special order.
- Filler and wrapping
- Non-hygroscopic PVC rod and/or polypropylene filler; polyester (Mylar) wrapping tape.
- Screen
- No metallic screen specified.
- Outer sheath
- Black PVC.
- Optional sheath
- Special flame-retardant PVC can be supplied on request; see PDF.
Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.
Read full datasheet — 8 pages ↗
CTW-FCVVS
600 V · 75 °CICEA S-61-402 (NEMA WC 5)
Flexible copper · PVC insulation
Copper tape screen
View details
- Applications
- Supervisory electrical equipment and station control circuits; outdoor installation in wet or dry cable trenches, as described in the datasheet.
- Reference standard
- ICEA S-61-402 (NEMA WC 5)
- Rated voltage / temperature
- 600 V; maximum conductor temperature 75 °C.
- Conductor
- Flexible bunched annealed copper.
- Nominal conductor sizes
- 0.5, 0.75, 1, 1.5, 2.5, 4, 6, 10 mm²; refer to the PDF for the listed combinations.
- Core configurations
- 2–30 cores, in the configurations listed in the PDF.
- Insulation
- Black PVC with number marking; other identification colours may be supplied to special order.
- Filler and wrapping
- Non-hygroscopic PVC rod and/or polypropylene filler; polyester (Mylar) wrapping tape.
- Bedding
- Black PVC.
- Screen
- Annealed copper tape.
- Separator
- Polyester (Mylar) tape.
- Outer sheath
- Black PVC.
- Optional sheath
- Special flame-retardant PVC can be supplied on request; see PDF.
Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.
Read full datasheet — 8 pages ↗
CTW-CVV
600 V · 70 °CIEC 60502-1
Stranded copper · PVC insulation
Unscreened
View details
- Applications
- Supervisory electrical equipment and station control circuits; outdoor installation in wet or dry cable trenches, as described in the datasheet.
- Reference standard
- IEC 60502-1
- Rated voltage / temperature
- 600 V; maximum conductor temperature 70 °C.
- Conductor
- Concentric stranded annealed copper.
- Nominal conductor sizes
- 1.5, 2.5, 4, 6, 10 mm²; refer to the PDF for the listed combinations.
- Core configurations
- 2–30 cores, in the configurations listed in the PDF.
- Insulation
- Black PVC with number marking; other identification colours may be supplied to special order.
- Filler and wrapping
- Non-hygroscopic PVC rod and/or polypropylene filler; polyester (Mylar) wrapping tape.
- Screen
- No metallic screen specified.
- Outer sheath
- Black PVC.
- Optional sheath
- Special flame-retardant PVC can be supplied on request; see PDF.
Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.
Read full datasheet — 6 pages ↗
CTW-CVVS
600 V · 70 °CIEC 60502-1
Stranded copper · PVC insulation
Copper tape screen
View details
- Applications
- Supervisory electrical equipment and station control circuits; outdoor installation in wet or dry cable trenches, as described in the datasheet.
- Reference standard
- IEC 60502-1
- Rated voltage / temperature
- 600 V; maximum conductor temperature 70 °C.
- Conductor
- Concentric stranded annealed copper.
- Nominal conductor sizes
- 1.5, 2.5, 4, 6, 10 mm²; refer to the PDF for the listed combinations.
- Core configurations
- 2–30 cores, in the configurations listed in the PDF.
- Insulation
- Black PVC with number marking; other identification colours may be supplied to special order.
- Filler and wrapping
- Non-hygroscopic PVC rod and/or polypropylene filler; polyester (Mylar) wrapping tape.
- Bedding
- Black PVC.
- Screen
- Annealed copper tape.
- Separator
- Polyester (Mylar) tape.
- Outer sheath
- Black PVC.
- Optional sheath
- Special flame-retardant PVC can be supplied on request; see PDF.
Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.
Read full datasheet — 6 pages ↗
CTW-CVV-SWA
600 V · 70 °CIEC 60502-1
Stranded copper · PVC insulation
Steel wire armour (SWA)
View details
- Applications
- Supervisory electrical equipment and station control circuits; outdoor installation in wet or dry cable trenches, as described in the datasheet.
- Reference standard
- IEC 60502-1
- Rated voltage / temperature
- 600 V; maximum conductor temperature 70 °C.
- Conductor
- Concentric stranded annealed copper.
- Nominal conductor sizes
- 1.5, 2.5, 4, 6, 10 mm²; refer to the PDF for the listed combinations.
- Core configurations
- 2–30 cores, in the configurations listed in the PDF.
- Insulation
- Black PVC with number marking; other identification colours may be supplied to special order.
- Filler and wrapping
- Non-hygroscopic PVC rod and/or polypropylene filler; polyester (Mylar) wrapping tape.
- Bedding
- Black PVC.
- Screen
- No metallic screen specified.
- Armour
- Galvanized steel wire armour.
- Separator
- Polyester (Mylar) tape.
- Outer sheath
- Black PVC.
- Optional sheath
- Special flame-retardant PVC can be supplied on request; see PDF.
Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.
Read full datasheet — 6 pages ↗
CTW-FCVV
600 V · 70 °CJIS C3401
Flexible copper · PVC insulation
Unscreened
View details
- Applications
- Supervisory electrical equipment and station control circuits; outdoor installation in wet or dry cable trenches, as described in the datasheet.
- Reference standard
- JIS C3401
- Rated voltage / temperature
- 600 V; maximum conductor temperature 70 °C.
- Conductor
- Flexible bunched annealed copper.
- Nominal conductor sizes
- 1, 1.5, 2.5, 4, 6 mm²; refer to the PDF for the listed combinations.
- Core configurations
- 2–30 cores, in the configurations listed in the PDF.
- Insulation
- Black PVC with number marking; other identification colours may be supplied to special order.
- Filler and wrapping
- Non-hygroscopic PVC rod and/or polypropylene filler; polyester (Mylar) wrapping tape.
- Screen
- No metallic screen specified.
- Outer sheath
- Black PVC.
- Optional sheath
- Special flame-retardant PVC can be supplied on request; see PDF.
Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.
Read full datasheet — 6 pages ↗
CTW-FCVVS
600 V · 70 °CJIS C3401
Flexible copper · PVC insulation
Copper tape screen
View details
- Applications
- Supervisory electrical equipment and station control circuits; outdoor installation in wet or dry cable trenches, as described in the datasheet.
- Reference standard
- JIS C3401
- Rated voltage / temperature
- 600 V; maximum conductor temperature 70 °C.
- Conductor
- Flexible bunched annealed copper.
- Nominal conductor sizes
- 1, 1.5, 2.5, 4, 6 mm²; refer to the PDF for the listed combinations.
- Core configurations
- 2–30 cores, in the configurations listed in the PDF.
- Insulation
- Black PVC with number marking; other identification colours may be supplied to special order.
- Filler and wrapping
- Non-hygroscopic PVC rod and/or polypropylene filler; polyester (Mylar) wrapping tape.
- Bedding
- Black PVC.
- Screen
- Annealed copper tape.
- Separator
- Polyester (Mylar) tape.
- Outer sheath
- Black PVC.
- Optional sheath
- Special flame-retardant PVC can be supplied on request; see PDF.
Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.
Read full datasheet — 6 pages ↗
CTW-CVVN-DSTA
750 V · 70 °CBS 6346:1997
Double steel tape armour (DSTA)
Nylon 12 protective layer
View details
- Applications
- Control signals, signal lamps, point machines and other signalling equipment within an interlocked signal area, as described in the datasheet.
- Reference standards
- BS 6346:1997, BS 6360:1991 and BS 6746.
- Rated voltage / temperature
- 750 V; maximum conductor temperature 70 °C.
- Conductor
- Plain annealed copper to BS 6360; solid or stranded according to the listed configuration.
- Nominal conductor sizes
- 1.5, 2.5, 4, 6, 10, 16 and 25 mm². Available combinations depend on core count; see PDF.
- Core configurations
- 2–30 cores, in the configurations listed in the PDF.
- Insulation and identification
- PVC Type TI1 to BS 6746; black cores with continuous number marking.
- Wrapping
- Wrapping tape around the core bundle, as shown in the construction drawing.
- Bedding sheath
- Black PVC Type TM1 to BS 6746.
- Armour
- Double galvanized steel tape armour (DSTA); tape thickness 0.2 mm.
- Overall sheath
- Black PVC Type TM1 to BS 6746, over the armour.
- Termite protective layer
- Nylon 12; thickness 0.5 mm, over the overall sheath.
- Outer protective sheath
- PVC Type TM1 to BS 6746, over the Nylon 12 layer.
- AC test voltage
- 3 kV, as specified in the supplied datasheet.
Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.
Read full datasheet — 5 pages ↗
CTW-NYCYControl cable
750 V · 70 °CTIS 11-2531 · VDE 0271
PVC insulation · Double sheath
Copper wire + tape screen
View details
- Applications
- Exposed installation or installation in raceways, in wet or dry locations, or direct burial, as described in the datasheet.
- Reference standard
- TIS 11-2531 / VDE 0271, where applicable
- Rated voltage / temperature
- 750 V; maximum conductor temperature 70 °C.
- Conductor
- Concentric stranded annealed copper.
- Nominal conductor sizes
- 2.5 mm²; see PDF for individual sizes and configurations.
- Core configurations
- 2, 3, 4, 5, 6, 7, 12, 19, 27 or 37 cores.
- Insulation and identification
- PVC. 2 cores: red / black; 3 cores: red / yellow / blue; 4 cores: red / yellow / blue / black. More than 4 cores: black with white number marking.
- Inner sheath
- Black PVC.
- Concentric screen
- Concentric copper wires with a helix of copper tape.
- Outer sheath
- Black PVC.
- Test voltage
- 2,500 V, as specified in the supplied datasheet.
Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.
Read full datasheet — 1 page ↗
CTW-NYCYPower cable
750 V · 70 °CTIS 11-2531 · VDE 0271
PVC insulation · Double sheath
Copper wire + tape screen
View details
- Applications
- Exposed installation or installation in raceways, in wet or dry locations, or direct burial, as described in the datasheet.
- Reference standard
- TIS 11-2531 / VDE 0271, where applicable
- Rated voltage / temperature
- 750 V; maximum conductor temperature 70 °C.
- Conductor
- Concentric stranded annealed copper.
- Nominal conductor sizes
- 1.5–300 mm²; see PDF for individual sizes and configurations.
- Core configurations
- 2, 3 or 4 cores.
- Insulation and identification
- PVC. 2 cores: red / black; 3 cores: red / yellow / blue; 4 cores: red / yellow / blue / black.
- Inner sheath
- Black PVC.
- Concentric screen
- Concentric copper wires with a helix of copper tape.
- Outer sheath
- Black PVC.
- Test voltage
- 2,500 V, as specified in the supplied datasheet.
Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.
Read full datasheet — 3 pages ↗
CTW-NYY-SWA
750 V · 70 °CApplied TIS 11-2531
PVC insulation · Double sheath
Steel wire armour (SWA)
View details
- Applications
- Exposed installation or installation in raceways, in wet or dry locations, or direct burial, as described in the datasheet.
- Reference standard
- Applied TIS 11-2531
- Rated voltage / temperature
- 750 V; maximum conductor temperature 70 °C.
- Conductor
- Solid or stranded annealed copper according to the listed size.
- Nominal conductor sizes
- 1–300 mm²; see PDF for individual sizes and configurations.
- Core configurations
- 2, 3 or 4 cores.
- Insulation and identification
- PVC. 2 cores: light grey / black; 3 cores: light grey / black / red; 4 cores: light grey / black / red / blue.
- Inner sheath
- Black PVC.
- Armour
- Galvanized steel wire armour.
- Outer sheath
- Black PVC.
- Test voltage
- 2,500 V, as specified in the supplied datasheet.
Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.
Read full datasheet — 3 pages ↗
CTW-RE-2Y(ST)Y-PR
300/500 V · 65 °CBS 5308 Part 1 Type 1
Collective aluminium foil screen
PE insulation · Unarmoured
View details
- Applications
- Transmission of analogue and digital signals in instrument and control systems. Indoor and outdoor installation in dry or wet locations on racks or in conduits. The supplied datasheet does not recommend direct burial and prohibits direct connection to a low-impedance source such as public mains electricity.
- Reference standard
- BS 5308 Part 1 Type 1
- Rated voltage / temperature
- 300/500 V; maximum conductor operating temperature +65 °C.
- Conductor
- Plain annealed copper to BS 6360; solid, flexible or stranded, depending on nominal size and the listed configuration.
- Nominal conductor sizes
- 0.5, 1.0, 1.5 mm²; available combinations vary by size.
- Core configuration
- Twisted pairs; 1–50 pairs. See PDF for the individual configurations.
- Insulation
- Polyethylene (PE) Type 03 to BS 6234.
- Wrapping
- At least one layer of polyester tape.
- Collective screen
- Aluminium foil in contact with a 0.5 mm² tinned-copper drain wire.
- Outer sheath
- Black PVC Type TM1 to BS 6746.
- Minimum bending radius
- 6 × overall cable diameter.
- Optional sheath
- Special flame-retardant PVC or low-smoke halogen-free (LSHF) material can be requested; refer to the PDF for the corresponding requirements.
Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.
Read full datasheet — 2 pages ↗
CTW-RE-2Y(ST)Y-PS
300/500 V · 65 °CBS 5308 Part 1 Type 1
Individual + collective screens
PE insulation · Unarmoured
View details
- Applications
- Transmission of analogue and digital signals in instrument and control systems. Indoor and outdoor installation in dry or wet locations on racks or in conduits. The supplied datasheet does not recommend direct burial and prohibits direct connection to a low-impedance source such as public mains electricity.
- Reference standard
- BS 5308 Part 1 Type 1
- Rated voltage / temperature
- 300/500 V; maximum conductor operating temperature +65 °C.
- Conductor
- Plain annealed copper to BS 6360; solid, flexible or stranded, depending on nominal size and the listed configuration.
- Nominal conductor sizes
- 0.5, 1.0, 1.5 mm²; available combinations vary by size.
- Core configuration
- Twisted pairs; 2–50 pairs. See PDF for the individual configurations.
- Insulation
- Polyethylene (PE) Type 03 to BS 6234.
- Individual pair screens
- Aluminium foil in contact with a 0.5 mm² tinned-copper drain wire for each screened pair.
- Wrapping
- At least one layer of polyester tape.
- Collective screen
- Aluminium foil in contact with a 0.5 mm² tinned-copper drain wire.
- Outer sheath
- Black PVC Type TM1 to BS 6746.
- Minimum bending radius
- 6 × overall cable diameter.
- Optional sheath
- Special flame-retardant PVC or low-smoke halogen-free (LSHF) material can be requested; refer to the PDF for the corresponding requirements.
Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.
Read full datasheet — 2 pages ↗
CTW-RE-2Y(ST)2YSWAY-PR
300/500 V · 65 °CBS 5308 Part 1 Type 2
Collective aluminium foil screen
PE insulation · SWA
View details
- Applications
- Transmission of analogue and digital signals in instrument and control systems. Indoor and outdoor installation in dry or wet locations on racks or in conduits. The supplied datasheet does not recommend direct burial and prohibits direct connection to a low-impedance source such as public mains electricity.
- Reference standard
- BS 5308 Part 1 Type 2
- Rated voltage / temperature
- 300/500 V; maximum conductor operating temperature +65 °C.
- Conductor
- Plain annealed copper to BS 6360; solid, flexible or stranded, depending on nominal size and the listed configuration.
- Nominal conductor sizes
- 0.5, 1.0, 1.5 mm²; available combinations vary by size.
- Core configuration
- Twisted pairs; 1–50 pairs. See PDF for the individual configurations.
- Insulation
- Polyethylene (PE) Type 03 to BS 6234.
- Wrapping
- At least one layer of polyester tape.
- Collective screen
- Aluminium foil in contact with a 0.5 mm² tinned-copper drain wire.
- Bedding
- Black PE Type 03.
- Armour
- Galvanized round steel wire (SWA).
- Outer sheath
- Black PVC Type TM1 to BS 6746.
- Minimum bending radius
- 8 × overall cable diameter.
- Optional sheath
- Special flame-retardant PVC or low-smoke halogen-free (LSHF) material can be requested; refer to the PDF for the corresponding requirements.
Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.
Read full datasheet — 2 pages ↗
CTW-RE-2Y(ST)2YSWAY-PS
300/500 V · 65 °CBS 5308 Part 1 Type 2
Individual + collective screens
PE insulation · SWA
View details
- Applications
- Transmission of analogue and digital signals in instrument and control systems. Indoor and outdoor installation in dry or wet locations on racks or in conduits. The supplied datasheet does not recommend direct burial and prohibits direct connection to a low-impedance source such as public mains electricity.
- Reference standard
- BS 5308 Part 1 Type 2
- Rated voltage / temperature
- 300/500 V; maximum conductor operating temperature +65 °C.
- Conductor
- Plain annealed copper to BS 6360; solid, flexible or stranded, depending on nominal size and the listed configuration.
- Nominal conductor sizes
- 0.5, 1.0, 1.5 mm²; available combinations vary by size.
- Core configuration
- Twisted pairs; 2–50 pairs. See PDF for the individual configurations.
- Insulation
- Polyethylene (PE) Type 03 to BS 6234.
- Individual pair screens
- Aluminium foil in contact with a 0.5 mm² tinned-copper drain wire for each screened pair.
- Wrapping
- At least one layer of polyester tape.
- Collective screen
- Aluminium foil in contact with a 0.5 mm² tinned-copper drain wire.
- Bedding
- Black PE Type 03.
- Armour
- Galvanized round steel wire (SWA).
- Outer sheath
- Black PVC Type TM1 to BS 6746.
- Minimum bending radius
- 8 × overall cable diameter.
- Optional sheath
- Special flame-retardant PVC or low-smoke halogen-free (LSHF) material can be requested; refer to the PDF for the corresponding requirements.
Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.
Read full datasheet — 2 pages ↗
CTW-RE-Y(ST)Y-PR
300/500 V · 65 °CBS 5308 Part 2 Type 1
Collective aluminium foil screen
PVC insulation · Unarmoured
View details
- Applications
- Transmission of analogue and digital signals in instrument and control systems. Indoor and outdoor installation in dry or wet locations on racks or in conduits. The supplied datasheet does not recommend direct burial and prohibits direct connection to a low-impedance source such as public mains electricity.
- Reference standard
- BS 5308 Part 2 Type 1
- Rated voltage / temperature
- 300/500 V; maximum conductor operating temperature +65 °C.
- Conductor
- Plain annealed copper to BS 6360; 0.5 and 0.75 mm² flexible conductors, or 1.5 mm² stranded conductors, as listed in the PDF.
- Nominal conductor sizes
- 0.5, 0.75, 1.5 mm²; available combinations vary by size.
- Core configuration
- Twisted pairs; 1–50 pairs. See PDF for the individual configurations.
- Insulation
- Polyvinyl chloride (PVC); refer to the PDF for identification and compound details.
- Wrapping
- At least one layer of polyester tape.
- Collective screen
- Aluminium foil in contact with a 0.5 mm² tinned-copper drain wire.
- Outer sheath
- Black PVC Type TM1 to BS 6746.
- Minimum bending radius
- 6 × overall cable diameter.
- Optional sheath
- Special flame-retardant PVC or low-smoke halogen-free (LSHF) material can be requested; refer to the PDF for the corresponding requirements.
Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.
Read full datasheet — 2 pages ↗
CTW-RE-Y(ST)Y-PS
300/500 V · 65 °CBS 5308 Part 2 Type 1
Individual + collective screens
PVC insulation · Unarmoured
View details
- Applications
- Transmission of analogue and digital signals in instrument and control systems. Indoor and outdoor installation in dry or wet locations on racks or in conduits. The supplied datasheet does not recommend direct burial and prohibits direct connection to a low-impedance source such as public mains electricity.
- Reference standard
- BS 5308 Part 2 Type 1
- Rated voltage / temperature
- 300/500 V; maximum conductor operating temperature +65 °C.
- Conductor
- Plain annealed copper to BS 6360; 0.5 and 0.75 mm² flexible conductors, or 1.5 mm² stranded conductors, as listed in the PDF.
- Nominal conductor sizes
- 0.5, 0.75, 1.5 mm²; available combinations vary by size.
- Core configuration
- Twisted pairs; 2–50 pairs. See PDF for the individual configurations.
- Insulation
- Polyvinyl chloride (PVC); refer to the PDF for identification and compound details.
- Individual pair screens
- Aluminium foil in contact with a 0.5 mm² tinned-copper drain wire for each screened pair.
- Wrapping
- At least one layer of polyester tape.
- Collective screen
- Aluminium foil in contact with a 0.5 mm² tinned-copper drain wire.
- Outer sheath
- Black PVC Type TM1 to BS 6746.
- Minimum bending radius
- 6 × overall cable diameter.
- Optional sheath
- Special flame-retardant PVC or low-smoke halogen-free (LSHF) material can be requested; refer to the PDF for the corresponding requirements.
Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.
Read full datasheet — 2 pages ↗
CTW-RE-Y(ST)Y-CO
300/500 V · 65 °CBS 5308 Part 2 Type 1
Collective aluminium foil screen
PVC insulation · Unarmoured
View details
- Applications
- Transmission of analogue and digital signals in instrument and control systems. Indoor and outdoor installation in dry or wet locations on racks or in conduits. The supplied datasheet does not recommend direct burial and prohibits direct connection to a low-impedance source such as public mains electricity.
- Reference standard
- BS 5308 Part 2 Type 1
- Rated voltage / temperature
- 300/500 V; maximum conductor operating temperature +65 °C.
- Conductor
- Plain annealed copper to BS 6360; 0.5 and 0.75 mm² flexible conductors, or 1.5 mm² stranded conductors, as listed in the PDF.
- Nominal conductor sizes
- 0.5, 0.75, 1.5 mm²; available combinations vary by size.
- Core configuration
- Multicore (CO); 2–40 cores. See PDF for the individual configurations.
- Insulation
- Polyvinyl chloride (PVC); refer to the PDF for identification and compound details.
- Wrapping
- At least one layer of polyester tape.
- Collective screen
- Aluminium foil in contact with a 0.5 mm² tinned-copper drain wire.
- Outer sheath
- Black PVC Type TM1 to BS 6746.
- Minimum bending radius
- 8 × overall cable diameter.
- Optional sheath
- Special flame-retardant PVC or low-smoke halogen-free (LSHF) material can be requested; refer to the PDF for the corresponding requirements.
Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.
Read full datasheet — 2 pages ↗
CTW-RE-Y(ST)YSWAY-CO
300/500 V · 65 °CBS 5308 Part 2 Type 2
Collective aluminium foil screen
PVC insulation · SWA
View details
- Applications
- Transmission of analogue and digital signals in instrument and control systems. Indoor and outdoor installation in dry or wet locations on racks or in conduits. The supplied datasheet does not recommend direct burial and prohibits direct connection to a low-impedance source such as public mains electricity.
- Reference standard
- BS 5308 Part 2 Type 2
- Rated voltage / temperature
- 300/500 V; maximum conductor operating temperature +65 °C.
- Conductor
- Plain annealed copper to BS 6360; 0.5 and 0.75 mm² flexible conductors, or 1.5 mm² stranded conductors, as listed in the PDF.
- Nominal conductor sizes
- 0.5, 0.75, 1.5 mm²; available combinations vary by size.
- Core configuration
- Multicore (CO); 2–40 cores. See PDF for the individual configurations.
- Insulation
- Polyvinyl chloride (PVC); refer to the PDF for identification and compound details.
- Wrapping
- At least one layer of polyester tape.
- Collective screen
- Aluminium foil in contact with a 0.5 mm² tinned-copper drain wire.
- Bedding
- Black PVC.
- Armour
- Galvanized round steel wire (SWA).
- Outer sheath
- Black PVC Type TM1 to BS 6746.
- Minimum bending radius
- 8 × overall cable diameter.
- Optional sheath
- Special flame-retardant PVC or low-smoke halogen-free (LSHF) material can be requested; refer to the PDF for the corresponding requirements.
Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.
Read full datasheet — 2 pages ↗
CTW-RE-Y(ST)YSWAY-PR
300/500 V · 65 °CBS 5308 Part 2 Type 2
Collective aluminium foil screen
PVC insulation · SWA
View details
- Applications
- Transmission of analogue and digital signals in instrument and control systems. Indoor and outdoor installation in dry or wet locations on racks or in conduits. The supplied datasheet does not recommend direct burial and prohibits direct connection to a low-impedance source such as public mains electricity.
- Reference standard
- BS 5308 Part 2 Type 2
- Rated voltage / temperature
- 300/500 V; maximum conductor operating temperature +65 °C.
- Conductor
- Plain annealed copper to BS 6360; 0.5 and 0.75 mm² flexible conductors, or 1.5 mm² stranded conductors, as listed in the PDF.
- Nominal conductor sizes
- 0.5, 0.75, 1.5 mm²; available combinations vary by size.
- Core configuration
- Twisted pairs; 1–50 pairs. See PDF for the individual configurations.
- Insulation
- Polyvinyl chloride (PVC); refer to the PDF for identification and compound details.
- Wrapping
- At least one layer of polyester tape.
- Collective screen
- Aluminium foil in contact with a 0.5 mm² tinned-copper drain wire.
- Bedding
- Black PVC.
- Armour
- Galvanized round steel wire (SWA).
- Outer sheath
- Black PVC Type TM1 to BS 6746.
- Minimum bending radius
- 8 × overall cable diameter.
- Optional sheath
- Special flame-retardant PVC or low-smoke halogen-free (LSHF) material can be requested; refer to the PDF for the corresponding requirements.
Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.
Read full datasheet — 2 pages ↗
CTW-RE-Y(ST)YSWAY-PS
300/500 V · 65 °CBS 5308 Part 2 Type 2
Individual + collective screens
PVC insulation · SWA
View details
- Applications
- Transmission of analogue and digital signals in instrument and control systems. Indoor and outdoor installation in dry or wet locations on racks or in conduits. The supplied datasheet does not recommend direct burial and prohibits direct connection to a low-impedance source such as public mains electricity.
- Reference standard
- BS 5308 Part 2 Type 2
- Rated voltage / temperature
- 300/500 V; maximum conductor operating temperature +65 °C.
- Conductor
- Plain annealed copper to BS 6360; 0.5 and 0.75 mm² flexible conductors, or 1.5 mm² stranded conductors, as listed in the PDF.
- Nominal conductor sizes
- 0.5, 0.75, 1.5 mm²; available combinations vary by size.
- Core configuration
- Twisted pairs; 2–50 pairs. See PDF for the individual configurations.
- Insulation
- Polyvinyl chloride (PVC); refer to the PDF for identification and compound details.
- Individual pair screens
- Aluminium foil in contact with a 0.5 mm² tinned-copper drain wire for each screened pair.
- Wrapping
- At least one layer of polyester tape.
- Collective screen
- Aluminium foil in contact with a 0.5 mm² tinned-copper drain wire.
- Bedding
- Black PVC.
- Armour
- Galvanized round steel wire (SWA).
- Outer sheath
- Black PVC Type TM1 to BS 6746.
- Minimum bending radius
- 8 × overall cable diameter.
- Optional sheath
- Special flame-retardant PVC or low-smoke halogen-free (LSHF) material can be requested; refer to the PDF for the corresponding requirements.
Refer to the original PDF for available sizes, dimensions, electrical characteristics and packing details.
Read full datasheet — 2 pages ↗