POWER CABLE COLLECTION

The right cable.
For every connection.

Explore medium and high voltage power cables.
View construction, specifications and datasheets in one place.

14Product families115 kVMaximum voltage in this collectionPDFTechnical datasheets

Select “View details” for specifications or “Download PDF” for the datasheet. Use Ctrl+F or your browser’s Find in Page to search.

Explore products (14)

Airport lighting01 / 14
Construction of FAA L-824 TYPE C 1 Core from the CTW datasheet

FAA L-824 TYPE C

5 kV / 1 Core

Copper conductor
Unarmoured

4–8 AWG• PDF 1 page
View details
Applications
For airport lighting and control systems. Suitable for conduit, duct, aerial and direct burial installations.
Voltage ratings in the datasheet
5 kV
Number of cores
1 Core
Size range across this product family
4–8 AWG (refer to the PDF for sizes at each voltage rating)
Conductor
Stranded annealed copper
Insulation
Cross-linked polyethylene (XLPE)
Metallic shield
No metallic shield
Armour
Unarmoured
Sheath / Outer layer
Black XLPE insulation; no separate sheath
Normal operating temperature
90°C
Reference standards in the datasheet
FAA L-824 Type C; ICEA S-96-659 / NEMA WC71-1999; ASTM B3 & B8

Refer to the original PDF tables for model-specific dimensions, current ratings and installation conditions.

Read full datasheet — 1 page ↗
Overhead cables02 / 14
Construction of PIC 1 Core from the CTW datasheet

PIC

25 / 35 kV / 1 Core

Aluminium conductor
Unarmoured

35–185 mm²• PDF 2 pages
View details
Applications
Partially insulated overhead distribution cable for installation on poles with pin insulators.
Voltage ratings in the datasheet
25 kV • 35 kV
Number of cores
1 Core
Size range across this product family
35–185 mm² (refer to the PDF for sizes at each voltage rating)
Conductor
Compacted stranded aluminium
Insulation
Cross-linked polyethylene (XLPE)
Metallic shield
No metallic shield
Armour
Unarmoured
Sheath / Outer layer
Track-resistant XLPE
Normal operating temperature
90°C
Reference standards in the datasheet
ICEA S-66-524 / MEA / PEA

Refer to the original PDF tables for model-specific dimensions, current ratings and installation conditions.

Read full datasheet — 2 pages ↗
Overhead cables03 / 14
Construction of SAC 1 Core from the CTW datasheet

SAC

15 / 25 / 35 kV / 1 Core

Aluminium conductor
Unarmoured

25–240 mm²• PDF 3 pages
View details
Applications
Insulated overhead distribution cable for installation on poles with spacers.
Voltage ratings in the datasheet
15 kV • 25 kV • 35 kV
Number of cores
1 Core
Size range across this product family
25–240 mm² (refer to the PDF for sizes at each voltage rating)
Conductor
Compacted stranded aluminium
Insulation
Cross-linked polyethylene (XLPE)
Metallic shield
No metallic shield
Armour
Unarmoured
Sheath / Outer layer
Track-resistant XLPE
Normal operating temperature
90°C
Reference standards in the datasheet
ICEA S-66-524 / MEA / PEA

Refer to the original PDF tables for model-specific dimensions, current ratings and installation conditions.

Read full datasheet — 3 pages ↗
Medium voltage04 / 14
Construction of CV · ICEA 100% 1 Core from the CTW datasheet

CV · ICEA 100%

5 / 15 / 25 / 35 kV / 1 Core

Copper conductor
Unarmoured

10–1,000 mm²• PDF 4 pages
View details
Applications
For urban distribution networks. Suitable for aerial, direct burial, conduit, open tray and underground duct installations.
Voltage ratings in the datasheet
5 kV • 15 kV • 25 kV • 35 kV
Number of cores
1 Core
Size range across this product family
10–1,000 mm² (refer to the PDF for sizes at each voltage rating)
Conductor
Compacted stranded annealed copper
Insulation
Cross-linked polyethylene (XLPE)
Metallic shield
Copper tape
Armour
Unarmoured
Sheath / Outer layer
PVC (ST2)
Normal operating temperature
90°C
Reference standards in the datasheet
ICEA S-66-524

Refer to the original PDF tables for model-specific dimensions, current ratings and installation conditions.

Read full datasheet — 4 pages ↗
Medium voltage05 / 14
Construction of CV · ICEA 133% 1 Core from the CTW datasheet

CV · ICEA 133%

15 / 25 kV / 1 Core

Copper conductor
Unarmoured

25–1,000 mm²• PDF 2 pages
View details
Applications
For urban distribution networks. Suitable for aerial, direct burial, conduit, open tray and underground duct installations.
Voltage ratings in the datasheet
15 kV • 25 kV
Number of cores
1 Core
Size range across this product family
25–1,000 mm² (refer to the PDF for sizes at each voltage rating)
Conductor
Compacted stranded annealed copper
Insulation
Cross-linked polyethylene (XLPE)
Metallic shield
Copper tape
Armour
Unarmoured
Sheath / Outer layer
PVC (ST2)
Normal operating temperature
90°C
Reference standards in the datasheet
ICEA S-66-524

Refer to the original PDF tables for model-specific dimensions, current ratings and installation conditions.

Read full datasheet — 2 pages ↗
Medium voltage06 / 14
Construction of CU/XLPE/PVC 1 Core from the CTW datasheet

CU/XLPE/PVC

3.6–36 kV / 1 Core

Copper conductor
Unarmoured

10–1,000 mm²• PDF 6 pages
View details
Applications
For urban distribution networks. Suitable for aerial, direct burial, conduit, open tray and underground duct installations.
Voltage ratings in the datasheet
1.8/3 (3.6) kV • 3.6/6 (7.2) kV • 6/10 (12) kV • 8.7/15 (17.5) kV • 12/20 (24) kV • 18/30 (36) kV
Number of cores
1 Core
Size range across this product family
10–1,000 mm² (refer to the PDF for sizes at each voltage rating)
Conductor
Compacted stranded annealed copper
Insulation
Cross-linked polyethylene (XLPE)
Metallic shield
Copper tape
Armour
Unarmoured
Sheath / Outer layer
PVC (ST2)
Normal operating temperature
90°C
Reference standards in the datasheet
IEC 60228; IEC 60502-1 (1.8/3 kV); IEC 60502-2 (higher voltage ratings)

Refer to the original PDF tables for model-specific dimensions, current ratings and installation conditions.

Read full datasheet — 6 pages ↗
Medium voltage07 / 14
Construction of CU/XLPE/AWA/PVC 1 Core from the CTW datasheet

CU/XLPE/AWA/PVC

3.6–36 kV / 1 Core

Copper conductor
AWA armour

10–1,000 mm²• PDF 6 pages
View details
Applications
For urban distribution networks. Suitable for aerial, direct burial, conduit, open tray and underground duct installations.
Voltage ratings in the datasheet
1.8/3 (3.6) kV • 3.6/6 (7.2) kV • 6/10 (12) kV • 8.7/15 (17.5) kV • 12/20 (24) kV • 18/30 (36) kV
Number of cores
1 Core
Size range across this product family
10–1,000 mm² (refer to the PDF for sizes at each voltage rating)
Conductor
Compacted stranded annealed copper
Insulation
Cross-linked polyethylene (XLPE)
Metallic shield
Copper tape
Armour
Aluminium wire armour (AWA)
Sheath / Outer layer
PVC (ST2)
Normal operating temperature
90°C
Reference standards in the datasheet
IEC 60228; IEC 60502-1 (1.8/3 kV); IEC 60502-2 (higher voltage ratings)

Refer to the original PDF tables for model-specific dimensions, current ratings and installation conditions.

Read full datasheet — 6 pages ↗
Medium voltage08 / 14
Construction of CU/XLPE/DATA/PVC 1 Core from the CTW datasheet

CU/XLPE/DATA/PVC

3.6–36 kV / 1 Core

Copper conductor
DATA armour

10–1,000 mm²• PDF 6 pages
View details

The original filename states DSTA, but the heading and construction specify DATA / Double aluminum tape. Please confirm the armour type before selection.

Applications
For urban distribution networks. Suitable for aerial, direct burial, conduit, open tray and underground duct installations.
Voltage ratings in the datasheet
1.8/3 (3.6) kV • 3.6/6 (7.2) kV • 6/10 (12) kV • 8.7/15 (17.5) kV • 12/20 (24) kV • 18/30 (36) kV
Number of cores
1 Core
Size range across this product family
10–1,000 mm² (refer to the PDF for sizes at each voltage rating)
Conductor
Compacted stranded annealed copper
Insulation
Cross-linked polyethylene (XLPE)
Metallic shield
Copper tape
Armour
Double aluminium tape armour (DATA), as stated in the PDF
Sheath / Outer layer
PVC (ST2)
Normal operating temperature
90°C
Reference standards in the datasheet
IEC 60228; IEC 60502-1 (1.8/3 kV); IEC 60502-2 (higher voltage ratings)

Refer to the original PDF tables for model-specific dimensions, current ratings and installation conditions.

Read full datasheet — 6 pages ↗
Medium voltage09 / 14
Construction of CU/XLPE/PVC 3 Cores from the CTW datasheet

CU/XLPE/PVC

3.6–36 kV / 3 Cores

Copper conductor
Unarmoured

10–400 mm²• PDF 6 pages
View details
Applications
For urban distribution networks. Suitable for aerial, direct burial, conduit, open tray and underground duct installations.
Voltage ratings in the datasheet
1.8/3 (3.6) kV • 3.6/6 (7.2) kV • 6/10 (12) kV • 8.7/15 (17.5) kV • 12/20 (24) kV • 18/30 (36) kV
Number of cores
3 Cores
Size range across this product family
10–400 mm² (refer to the PDF for sizes at each voltage rating)
Conductor
Compacted stranded annealed copper
Insulation
Cross-linked polyethylene (XLPE)
Metallic shield
Copper tape
Armour
Unarmoured
Sheath / Outer layer
PVC (ST2)
Normal operating temperature
90°C
Reference standards in the datasheet
IEC 60228; IEC 60502-1 (1.8/3 kV); IEC 60502-2 (higher voltage ratings)

Refer to the original PDF tables for model-specific dimensions, current ratings and installation conditions.

Read full datasheet — 6 pages ↗
Medium voltage10 / 14
Construction of CU/XLPE/SWA/PVC 3 Cores from the CTW datasheet

CU/XLPE/SWA/PVC

3.6–36 kV / 3 Cores

Copper conductor
SWA armour

10–400 mm²• PDF 6 pages
View details
Applications
For urban distribution networks. Suitable for aerial, direct burial, conduit, open tray and underground duct installations.
Voltage ratings in the datasheet
1.8/3 (3.6) kV • 3.6/6 (7.2) kV • 6/10 (12) kV • 8.7/15 (17.5) kV • 12/20 (24) kV • 18/30 (36) kV
Number of cores
3 Cores
Size range across this product family
10–400 mm² (refer to the PDF for sizes at each voltage rating)
Conductor
Compacted stranded annealed copper
Insulation
Cross-linked polyethylene (XLPE)
Metallic shield
Copper tape
Armour
Galvanized steel wire armour (SWA)
Sheath / Outer layer
PVC (ST2)
Normal operating temperature
90°C
Reference standards in the datasheet
IEC 60228; IEC 60502-1 (1.8/3 kV); IEC 60502-2 (higher voltage ratings)

Refer to the original PDF tables for model-specific dimensions, current ratings and installation conditions.

Read full datasheet — 6 pages ↗
Medium voltage11 / 14
Construction of CU/XLPE/DSTA/PVC 3 Cores from the CTW datasheet

CU/XLPE/DSTA/PVC

3.6–36 kV / 3 Cores

Copper conductor
DSTA armour

10–400 mm²• PDF 6 pages
View details
Applications
For urban distribution networks. Suitable for aerial, direct burial, conduit, open tray and underground duct installations.
Voltage ratings in the datasheet
1.8/3 (3.6) kV • 3.6/6 (7.2) kV • 6/10 (12) kV • 8.7/15 (17.5) kV • 12/20 (24) kV • 18/30 (36) kV
Number of cores
3 Cores
Size range across this product family
10–400 mm² (refer to the PDF for sizes at each voltage rating)
Conductor
Compacted stranded annealed copper
Insulation
Cross-linked polyethylene (XLPE)
Metallic shield
Copper tape
Armour
Double steel tape armour (DSTA)
Sheath / Outer layer
PVC (ST2)
Normal operating temperature
90°C
Reference standards in the datasheet
IEC 60228; IEC 60502-1 (1.8/3 kV); IEC 60502-2 (higher voltage ratings)

Refer to the original PDF tables for model-specific dimensions, current ratings and installation conditions.

Read full datasheet — 6 pages ↗
Medium voltage12 / 14
Construction of CU/XLPE/CWS/PE 1 Core from the CTW datasheet

CU/XLPE/CWS/PE

3.6–36 kV / 1 Core

Copper conductor
Unarmoured

10–1,000 mm²• PDF 6 pages
View details
Applications
For urban distribution networks. Suitable for aerial, direct burial, conduit, open tray and underground duct installations.
Voltage ratings in the datasheet
1.8/3 (3.6) kV • 3.6/6 (7.2) kV • 6/10 (12) kV • 8.7/15 (17.5) kV • 12/20 (24) kV • 18/30 (36) kV
Number of cores
1 Core
Size range across this product family
10–1,000 mm² (refer to the PDF for sizes at each voltage rating)
Conductor
Compacted stranded annealed copper
Insulation
Cross-linked polyethylene (XLPE)
Metallic shield
Copper wires with copper contact tape
Armour
Unarmoured
Sheath / Outer layer
PE (ST7)
Normal operating temperature
90°C
Reference standards in the datasheet
IEC 60228; IEC 60502-1 (1.8/3 kV); IEC 60502-2 (higher voltage ratings)

Refer to the original PDF tables for model-specific dimensions, current ratings and installation conditions.

Read full datasheet — 6 pages ↗
High voltage13 / 14
Construction of CU/XLPE/CWS/PE 1 Core from the CTW datasheet

CU/XLPE/CWS/PE

69 kV / 1 Core

Copper conductor
Unarmoured

240–1,000 mm²• PDF 1 page
View details
Applications
High voltage cable for urban networks. Suitable for ducts, trays and direct burial, including continuous water immersion as specified in the datasheet.
Voltage ratings in the datasheet
69 kV
Number of cores
1 Core
Size range across this product family
240–1,000 mm² (refer to the PDF for sizes at each voltage rating)
Conductor
Compacted stranded annealed copper
Insulation
Cross-linked polyethylene (XLPE)
Metallic shield
Copper wires with copper contact tape
Armour
Unarmoured
Sheath / Outer layer
PE (ST7)
Normal operating temperature
90°C
Reference standards in the datasheet
IEC 60228; IEC 60840

Refer to the original PDF tables for model-specific dimensions, current ratings and installation conditions.

Read full datasheet — 1 page ↗
High voltage14 / 14
Construction of CU/XLPE/CWS/PE 1 Core from the CTW datasheet

CU/XLPE/CWS/PE

115 kV / 1 Core

Copper conductor
Unarmoured

400–1,000 mm²• PDF 1 page
View details
Applications
High voltage cable for urban networks. Suitable for ducts, trays and direct burial, including continuous water immersion as specified in the datasheet.
Voltage ratings in the datasheet
115 kV
Number of cores
1 Core
Size range across this product family
400–1,000 mm² (refer to the PDF for sizes at each voltage rating)
Conductor
Compacted stranded annealed copper
Insulation
Cross-linked polyethylene (XLPE)
Metallic shield
Copper wires with copper contact tape
Armour
Unarmoured
Sheath / Outer layer
PE (ST7)
Normal operating temperature
90°C
Reference standards in the datasheet
IEC 60228; IEC 60840

Refer to the original PDF tables for model-specific dimensions, current ratings and installation conditions.

Read full datasheet — 1 page ↗
No matching products found

Try a different search term or clear the filters.

Hero image is illustrative. Construction images and specifications are based on CTW datasheets.
Check the voltage rating, size and installation conditions in the PDF before selection.